- Fully automatic control system (also can be operated manually)
- Control the addition of water, clay and various auxiliary materials
- Stable control of the strength and compression ratio of casting sand through humidity and temperature
- Automatically adjust the clay addition through the strength and compression ratio data
- Daily data analysis and recording
- Thermocouple: Detect the sand return temperature
- Weighing sensor: to detect the weight of a single batch
- Humidity probe: detect humidity with current value
- Take sand samples from the outlet of the sand mixer: determine the compressibility
- Record physical/chemical parameters
- Record process parameters
- Display and query production parameters
- Record process parameters
- Sampling test instrument & PLC automatic console (standard configuration)
- Moisture/temperature probe (standard)
- Water filling system (standard configuration)
- Pneumatic clay conveyor (optional)
- Sand storage bucket weighing system (optional)